DIVLABS Intensity Electrosurgical Unit
With micro controller assisted quick response technology

Computerized programable quick response technology monitors the tissue impedance and adjusts the power output to provide the user consistent performance, reducing the need to adjust power settings for different types of tissues. On site program facility possible. True digital power readout with dossage error control. Self diagnostic mode & spark sensor technology.
  AdvancedPerformance Features   Advanced Safety Features   Enhanced Operating Convenience  
 
Monopular-Computer
Controlled intelligent
Cut with Feedback
Response System
1. Three Cut modes-
(Auto Cut-Optional)
(a) Pure cut suitable for under water cutting (TURP, TUVP & TCRE) with URO-CUT, which eliminates lag time in initiating cut especially suited for urological procedure.
(b) Blend - modes - cutting with heamostasis for LLETZ/LEEP procedures Endocut(Gastrocut)-Optional 2. Three Coag modes -
(Auto Coag-Optional)
(a) Desiccation/Soft- for
low voltage Soft
coagulation suitable for
laproscopic & delicate
tissue work.Coagulation for minimal smoke generation
(b) Spray for non-contact
large tissue area
coagulation with minimum
depth of necrosis.
Bipolar-SLS (Computer Controlled Self Limiting System-Unmodulated- Auto Optional)
1. Micro- for delicate
tissue work by controlled
desiccation without
charring, adhesion or
blanching of adjacent
tissue (opthalmic & nuero-
surgery).
2. Macro- for new
generation of macro
bipolar cutting instruments (Tri-polar) for LAVH procedure etc. When used with BIPOL probes provides excellent tamponade capabilities.
  1. It also deactivates the unit & alarms in case of any discontinuity in the patient plate cord. Exclusive PEM (Patient Electrode monitoring)

2. Isolated RF output directs current to return back to the generator to reduce the risk of Alternate site burns & ensure patient safety in case of any discontinuity in patient plate cord. This current has no reference to ground so it does not cause notice able interference with ECG monitor, Cardiac pace maker etc.


3.
Independent activation
of hand switching, foot switching & bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.

4. Class ‘2’ leakage cancelling, a must for lengthy procedure like Cardiac surgery (CABG) etc.

 


1. Dual generator System- two independent Monopolar Handswitching outputs.

2. Separate Bipolar generator controls and footswitch with auto selectivity reduces the dependency on the operating room staff during the procedure.

3. Two independent handswitching monopolar outputs and one handswitching bipolar output combined with Laproscopic Clipons, eleminated the need of footswitches during endoscopic procedures.

4. Ergonomically designed trolley to house diathermy, accessories, argon unit with cylinders and smoke evacuator.

5. Comprehensive clinical training network through workshops, seminars, videos & literatures.

UPGRADATIONS

1. Easily upgradable into Argon-Beamer with DIV-ARGON Module

2.Compatible with DIV-VAC smoke evacuator

3. Upgradable with DIV-BCM Bipolar current monitor

4. Compatible with DIV-AES Active electrode safety system

5. Compatible with DIV-RFTA Radio frequency thermal ablation

 
TECHNICAL SPECIFICATIONS
 
Partner Sites ::-
http://ligasealer.com , http://quadrf.com , http://plasmaeffect.com , http://rfscalpel.com
Copyright Reserved @ Divlabs(india)2006 design by:. amritadatasoft