DIVLABS Intensity Electrosurgical Unit
With micro controller assisted quick response technology

CComputerized quck response technology monitors the tissue impedance and adjusts the power output to provide the user consistent performance, reducing the need to adjust power settings for different types of tissue. Ten on site program facility possible. True digital power readout with dossage error control self diagnostic mode & Spark sensor technology
  AdvancedPerformance Features   Advanced Safety Features   Enhanced Operating Convenience  
 


Monopular-Computer
Controlled intelligent Cut with Feedback Response System

1. Two Cut Modes (Auto Cut Optional)

(a) Pure cut (Advance-urocut)
suitable for under water cutting (TURP, TUVP & TCRE) with URO-CUT, which eliminates lag time in initiating cut especially suited for urological procedure.

2. Two Coag Modes- (AUto Coag-Optional)
(a) Desiccation/Soft
- for low voltage soft coagulation suitable for laproscopic & delicate tissue work. Coagulation for minimal smoke generation.

(b) Spray for non-contact large tissue area coagulation with minimum depth of necrosis.

Bipolar-SLS (Computer controlled Self Limiting System-Unmodulated-Auto Optional)

1. Micro- for delicate tissue work by controlled desiccation without charring, adhesion or blanching of adjacent tissue. (opthalmic & nuero-surgery).

2. Macro-for new generation of macro bipolar cutting instruments (Tri-polar) for LAVH procedure etc. when used with BIPOL probes provides excellent tamponade capabilities.

 

  1. It also deactivates the unit & alarms in case of any discontinuity in the patient plate cord. Exclusive PEM (Patient Electrode monitoring)

2.Isolated RF output directs current to return back to the generator to reduce the risk of Alternate site burns & ensure patient safety in case of any discontinuity in patient plate cord. This current has no reference to ground so it does not cause notice able interference with ECG monitor, Cardiac pace maker etc.



3.Independent activation
of hand switching, foot switching & bipolar output to protect against inadvertent output from an idle accessory lying on or near the patient or surgical staff.

Class ‘2’ leakage cancelling, a must for lengthy procedure like Cardiac surgery (CABG) etc.

4. Class '2' Leakage Cancelling, a must for lengthy procedure like Cardiac surgery (CABG) etc.

 

1. Independent monopolar outputs and one handswitching bipolar output combined with Laroscopic Clipons, eleminates the need of footswitches during endoscopic procedures.

2. Ergonomically designed trolley to house diathermy, accessories, argon unit with cylinders and smoke evacuator.

3. Comprehensive clinical training network through workshops, seminars, videos & literatures.

4. Smart Modular Technology for fast & effectirve after sales support (serves).

UPGRADATION
1. TUAP- Trans Urethral ablation of prostrate RF Ablation

2. Modular Upgradation and under saline procedures
(a) TURP/TCRE
(b) Arthroscopy
(c) Liver Resection

 

 
TECHNICAL SPECIFICATIONS
 
Partner Sites ::-
http://ligasealer.com , http://quadrf.com , http://plasmaeffect.com , http://rfscalpel.com
Copyright Reserved @ Divlabs(india)2006 design by:. amritadatasoft