Monopular-Computer
Controlled intelligent
Cut with Feedback
Response System
1. Three Cut modes-
(Auto Cut-Optional)
(a) Pure cut suitable for
under water cutting
(TURP, TUVP & TCRE) with
URO-CUT, which eliminates
lag time in initiating cut
especially suited for
urological procedure.
(b) Three Blend - modes
(program)
(c) Endocut(Gastrocut) - for G.I Surgery
2. Three Coag modes -
(Auto Coag-Optional)
(a) Desiccation/Soft- for
low voltage Soft
coagulation suitable for
laproscopic & delicate
tissue work.
(b) Fulgurate/Forced -
non contact Coagulation for minimal smoke generation
(c) Spray for non-contact
large tissue area
coagulation with minimum
depth of necrosis.
Bipolar-SLS
(Computer
Controlled Self Limiting
System-Unmodulated-Auto Optional)
1. Micro- for delicate
tissue work by controlled
desiccation without
charring, adhesion or
blanching of adjacent
tissue (opthalmic & nuero-
surgery).
2. Macro- for new
generation of macro
bipolar cutting instruments (Tri-polar) for LAVH procedure
etc. When used with BIPOL probes provides excellent tamponade capabilities.
3.Vessel ligation system(VLS) high-
pressure vessel sealing
with VLS artery
forcep. |
|
1. PPCQM- Patient to Patient plate contact
Quality monitoring
technology- monitors the quality & quantity of contact
between the patient & the patient plate. If this contact is not proper
the unit deactivates & alarms, thus eliminating any risk of Passive
Electrode site burns.
2. It deactivates the unit & alarms in case of any discontiniuity in
the patient plate core. Exclusive PEM (Patient Electrode monitoring)
3. Isolated RF output directs current to return
back to the generator to reduce the risk of Alternate site burns & to ensure patient safety in case of any discontinuity in
patient plate cord. This current has no reference to ground so it does
not cause notice able interference with ECG monitor, Cardiac pace maker
etc.
4. Independent activation of hand switching, foot switching
& bipolar output to protect against inadvertent output from an idle
accessory lying on or near the patient or surgical staff.
5. Class ‘2’ leakage cancelling, a must for
lengthy procedure like Cardiac surgery (CABG) etc. |
|

1. Dual generator System- two independent Monopolar Handswitching
outputs.
2. Separate Bipolar generator controls and footswitch with auto selectivity
reduces the dependency on the operating room staff during the procedure.
3. Two independent handswitching monopolar outputs and one handswitching
bipolar output combined with Laproscopic Clipons, eleminated the need
of footswitches during endoscopic procedures.
4. Ergonomically designed trolley to house diathermy, accessories, argon
unit with cylinders and smoke evacuator.
5. Comprehensive clinical training network through workshops, seminars, videos
& literatures.
UPGRADATIONS
1. Easily upgradable into Argon-Beamer with DIV-ARGON Module
2. Compatible with DIV-VAC smoke evacuator
3. Upgradable with DIV-BCM Bipolar current monitor
4. Compatible with DIV-AES Active electrode safety system
5. Compatible with DIV-RFTA Radio frequency thermal ablation |
|